Flagship · Monitored Drying

MMS90Intelligent moisture management
for transformer oil — 24/7.

An on-line single-cylinder dehydration system that quietly removes water from transformer insulation before it can rob your asset of life — backed by a PLC, dual sensors and 10 years of onboard data.

Brochure Tech Spec
MMS90 moisture management system
● LIVE · PLC ONLINE
H2O 8.2 ppm · 52 °C
≤ 10ppm
Moisture target
300LPH
Flow rate
10years
Onboard data
IP56rated
Protection
Inside MMS90

Engineered to be seen.

Outdoor EnclosureInternal LayoutHMI TouchscreenIn the Field
MMS90 · view
Outdoor Enclosure
IP56 · 380 KG · 230 VAC
sys.features / pipeline

Built for uptime. Designed for engineers.

Six engineered stages — from always-on operation to fail-safe isolation — work as one continuous moisture-management pipeline.

stage 01 / 06
f.01 // always-on

On-line continuous operation

24/7 dehydration without taking the transformer offline.

01 / 06
use cases / live

Where MMS90 earns its place.

Hover or tap any scenario — see how MMS90 performs across the utility, renewables and industrial worlds.

All applications
// scenario.detail
Power generation

Generator Step-Up (GSU)

Keep critical GSU insulation dry under heavy thermal cycling.

−72%
Moisture drop
99.9%
Avg. uptime
< 18mo
Payback
  • Continuous on-load drying
  • Resilient to thermal cycling
  • Zero outage installation
Trusted on the grid

Operators running MMS90 today

Selected utilities, TSOs and industrial operators deploying MMS90 across transmission, generation, and renewables fleets.

Dubai Electricity & Water Authority
Emirates Global Aluminium
Cirebon Power
CM Werkz Singapore
AZ Tech
SBS Transit
Sunban Power
Data Entry Thailand
Dubai Electricity & Water Authority
Emirates Global Aluminium
Cirebon Power
CM Werkz Singapore
AZ Tech
SBS Transit
Sunban Power
Data Entry Thailand
Gohan Solar Power
Maharashtra State Electricity Transmission
RPC Public Company Limited
Taiwan Power Research Institute
Transpower Singapore
PTT Global Chemical
NPS Services
Leadfar Technologies
Gohan Solar Power
Maharashtra State Electricity Transmission
RPC Public Company Limited
Taiwan Power Research Institute
Transpower Singapore
PTT Global Chemical
NPS Services
Leadfar Technologies
Sizing tool

Do you actually need MMS90?

Answer four quick questions about your transformer and we'll give you an instant indication. No data leaves the page.

Moisture trend ≥ 20 ppm is your early warning band.
Critical / GSU assets justify continuous dehydration.
Older fleets benefit from monitored intervention.
20,000 L
25 ppm
15 yrs
Asset risk index
72/100
MMS90 strongly recommended

Your asset profile shows real moisture risk. Continuous on-line dehydration with MMS90 will materially extend insulation life.

Send this assessment to engineering
Technical specifications

Every number that matters.

MMS90 ships with a complete installation kit and is supported by a one-year factory warranty through our worldwide network of authorized representatives.

Download full spec sheet
Flow rate
100–300 LPH (motor setting)
Moisture management
to ≤ 10 ppm
Media volume
50 kg
Particulate removal
1 / 3 / 6 / 12 micron (spin-on)
Dimensions (H×W×D)
1770 × 860 × 775 mm
Weight
380 kg
Enclosure
Mild steel 2.5 mm, RAL 7035, IP56
Cylinder & piping
Stainless steel 316
Oil temp range
+2 °C to +95 °C
Ambient temp range
0 °C to +65 °C
Electrical
230 VAC, 50/60 Hz, 360 W, 1Ø
Comms
Modbus RTU · DNP3 · TCP/IP · IEC 61850
Display
4-inch touch HMI
Data storage
8 GB · ~10 years
Ready when you are

Specify MMS90 for your next transformer.

Our engineering team will size, quote and commission MMS90 for any asset in your fleet — typically 5 hours to install, 1 hour to commission.

DryTrans AI
Online · Neural Link Active

Hello and Welcome to DryTrans. How can I help you today?