FAQs
1) New transformers are meant to carry some moisture in the paper insulation as completely dry paper is too brittle and is not mechanically strong.
2) Free breathing transformers will add some moisture from the atmosphere through the conservator and through the
breather.
3) Moisture creation inside the transformer paper insulation during normal operating conditions. This is a never-ending cycle, one that cannot be stopped. As the paper is subjected to heat and starts to degrade, the cellulose chain breaks apart to form water which is then dissolved into the oil. As the paper degrades further, more moisture is created and further degrades the paper creating moisture and so on.
Continuous Online Moisture Management Systems for Oil filled transformers are a crucial necessity of any maintenance
department.
It is now accepted, that no matter the oil filtration efforts, the transformer will never be rid of moisture. Once we accept this reality we are left with the only option, manage moisture effectively. If we cannot remove all the moisture from a transformer, we must manage its presence and not allow it to affect the reliability of the transformer.
This will require the use of an online moisture management system that is permanently affixed to the transformer and continually filters the moisture from the oil. Over 98% of moisture in a transformer is held within the solid insulation, and the oil acts as the medium to get to this moisture. Over time as the management system continues its operation and removes the moisture from the oil, the moisture from the solid insulation migrates to the oil and the process continues. It is absolutely imperative that the moisture be managed from an early stage to keep the transformer as healthy as possible and extend its operational life.
The oil dehydration rates of the on-line systems are dependent on various factors: moisture content of the oil, temperatures, oil quality, load, faults within the transformer if any and others.
Power consumption is 1.3 Amps at 230 VAC at the highest speed motor setting of 500 LPH.
At present we are offering a standard warranty of 12 months from the date of commissioning or 18 months from the date of dispatch, whichever comes first. In special circumstances, we are willing to offer an extended warranty up to 24 months from the date of commissioning. This can be looked at on a case to case basis.
The TRAM series was developed to allow the user to remove moisture and at the same time reduce the acidity levels in transformer oil. The TRAM series is a double cylinder system that comes in the TR5 / TR20 / TR50 / and MMS90 formats. Due to its complete flexibility, users can choose the media in each cylinder depending on the requirement.
Yes. Either with the existing single cylinder design or the double cylinder TRAM series, acidity can be reduced by using activated alumina zeolite material as the media.